====== MKWare_AddItemSNValues ======
As in the //MKWare_AddItemSN// function block, the PLC creates a ProductSN and stores new product data for this product in the //MK|Ware// database.
===== VAR_INPUT =====
VAR_INPUT
PDAtoPLC_ItemAdded: BOOL; (* Output from MK|Ware: variable is set to TRUE when a product serial number has been generated. *)
Enable: BOOL := TRUE; (* Reset all signals. *)
AddItem: BOOL; (* Start signal to request a new ProductSN. *)
ProductDesignation: STRING; (* Product designation *)
ProductSN: STRING; (* Contains the ProductSN for the product. *)
bValue1: BOOL; (* Value 1 of type BOOL *)
bValue2: BOOL; (* Value 2 of type BOOL *)
bValue3: BOOL; (* Value 3 of type BOOL *)
bValue4: BOOL; (* Value 4 of type BOOL *)
bValue5: BOOL; (* Value 5 of type BOOL *)
bValue6: BOOL; (* Value 6 of type BOOL *)
bValue7: BOOL; (* Value 7 of type BOOL *)
bValue8: BOOL; (* Value 8 of type BOOL *)
iValue1: INT; (* Value 1 of type INT *)
sValue1: STRING; (* Value 1 of type STRING *)
TimeoutTime: TIME :=t#10S; (* Value for timeout. *)
DelayTime: TIME :=t#300ms; (* Value for delay time. )
END_VAR
===== VAR_OUTPUT =====
VAR_OUTPUT
PDAfromPLC_AddItem: BOOL; (* Output to MK|Ware: If the status is TRUE, a ProductSN will be generated. *)
PDAfromPLC_ProductDesignation: STRING; (* Output to MK|Ware: Contains the current product. *)
PDAfromPLC_ProductSN: STRING; (* Output to MK|Ware: Contains the ProductSN for the product. *)
PDAfromPLC_bValue[1..N]: BOOL; (* Output to MK|Ware: This variable transfers product data of the type BOOL (e.g. OK/NOK). *)
PDAfromPLC_iValue1: BOOL; (* Output to MK|Ware: This variable transfers product data of type INTEGER (e.g. nest number). *)
PDAfromPLC_sValue1: STRING; (* Output to MK|Ware: This variable transfers product data of the type STRING (e.g. recipe name). *)
TimeoutError: BOOL; (* A TimeoutError is triggered after a specified period of time has elapsed. *)
Busy: BOOL; (* Is TRUE after start signals and FALSE after an abort or the return message from MK|Ware. *)
ItemAdded: BOOL; (* Pass-through signal of MKWare. *)
Error: STRING; (* Description of the error for error analysis *)
ErrorID: INT; (* Error ID for error analysis *)
END_VAR