A work center has at least two storage bins
Additional storage bins can be defined for work centers, e.g. to store material received jointly from several work centers. These collection points can also be a PVB. There may be exactly one HU at the PVB, the other storage bins may contain several containers.
With this function module, a material container is registered, deregistered and reregistered at a work center by scanning the HU number.
Variable Name | Type | Content |
---|---|---|
General | ||
IV_ARBPL | String | name of the work center |
IV_AUFNR | String | order number |
IV_MENGE | String | quantity (optional) |
IV_PID | String | HU-number |
IV_WERKS | String | plant number |
IV_PUFFER | String | X = post to buffer (normally from buffer to work center) |
IV_PVB | String | X = post to PVB |
IV_SKIP_WARE | String | not used in this function block |
Variable Name | Type | Content |
---|---|---|
General | ||
EV_Error | String | X=error occurred |
The return value is AA_FEHLERTEXT, a variable of data type String. It contains more detailed information about the error in case of an error. If EV_ERROR does not show an error, other status messages can also be located here. Therefore EV_ERROR must be evaluated for error checking and not only AA_FEHLERTEXT.